Wacker Neuson - E3000 HYD SUR HTR,6KW GEN, LB, EXT SVC - 5100056441
Specs |
|
Dimensions |
|
L x W x H in |
181 x 91 x 94 |
Operating weight lb |
|
Shipping weight lb |
|
Operating weight With Lift Bail lb |
9,290 |
Shipping weight With Lift Bail lb |
7,815 |
Heat transfer fluid Capacity US gal |
115 |
Hose Lengths ft |
3000 |
Quantity Hose Reels |
2 |
Quantity Circulation Loops |
2 |
Temperature monitor |
Digital |
Operating data |
|
Pump performance per pump US gal/h |
265 |
Flow velocity per Circulation Loop US gal/h |
265 |
Hose pressure Normal Operating psi |
110 |
Heating power Gross Input BTU/h |
385,000 |
Heat efficiency % |
83 |
Operating temperature ° F |
180 |
Capacity Thaw (std) ft² |
3,000 |
Capacity Thaw (w/acc) ft² |
6,000 |
Capacity Cure (std) ft² |
6,000 |
Capacity Cure (w/acc) ft² |
18,000 |
Capacity Frost (std) ft² |
9,000 |
Capacity Frost (w/acc) ft² |
27,000 |
Capacity Air Heat (w/acc) ft³ |
525,000 |
Generator model |
Mecc Alte |
Engine performance Generator kW |
6.5 |
Rated current A |
30 |
Rated voltage V |
120 |
Engine / Motor manufacturer |
Kohler KDW 1003 |
Engine / Motor type |
3-Cylinder Liquid Cooled |
Displacement in³ |
61 |
Engine performance hp |
14.5 |
Engine RPM rpm |
1800 |
Fuel type |
Winter Blend Diesel |
Fuel consumption Generator US gal/h |
0.61 |
Fuel consumption Burner US gal/h |
2.75 |
Tank capacity Useable Fuel US gal |
222 |
Tank capacity Oil US qt |
75 |
Runtime @ 100% Burner Run Percentage h |
81 |
Runtime @ 75% Burner Run Percentage h |
108 |
Wacker Neuson - E3000 HYD SUR HTR,6KW GEN, LB, EXT SVC - 5100056441
Cold weather construction comes with its challenges. Frozen ground, slow concrete curing, and harsh site conditions can delay projects and increase costs. To stay productive, contractors rely on professional-grade heaters like the Wacker Neuson - E3000 HYD SUR HTR,6KW GEN, LB, EXT SVC - 5100056441.
This advanced hydronic surface heater delivers safe, efficient, and even heating for ground thawing, concrete curing, and frost prevention. Built with Wacker Neuson’s signature durability and enhanced with extended service (EXT SVC) features, this unit ensures maximum uptime on demanding job sites. In this guide, we’ll explore its specifications, benefits, applications, and best practices to help you understand why the E3000 is a must-have solution for cold-weather work.
What Is the Wacker Neuson E3000 HYD SUR HTR?
The Wacker Neuson - E3000 HYD SUR HTR,6KW GEN, LB, EXT SVC - 5100056441 is a hydronic heating system designed to circulate a heated glycol mixture through hoses laid over surfaces or embedded in curing concrete. Unlike direct-fired heaters, the E3000 distributes consistent, flameless, safe heat.
This model includes:
-
A 6kW generator for independent operation.
-
Load Bank (LB) functionality for generator protection.
-
Extended Service (EXT SVC) capability, minimizing downtime.
With these features, it’s one of the most reliable hydronic heaters available for professional construction environments.
Key Features of the E3000 HYD SUR HTR
-
Integrated 6kW Generator
-
Supplies dedicated power for heater operation and small auxiliary tools.
-
Reduces reliance on jobsite power sources.
-
-
Hydronic Heating Technology
-
Circulates heated glycol through up to 3,000 feet of hose.
-
Provides even heat distribution across large areas.
-
-
Extended Service (EXT SVC)
-
Designed for longer maintenance intervals.
-
Keeps the machine running in continuous-duty environments.
-
-
Load Bank (LB) Functionality
-
Protects the generator and maintains electrical efficiency.
-
Ensures reliable operation even under varying loads.
-
-
Trailer-Mounted Design
-
Forklift pockets and towable frame for easy mobility.
-
Quick setup reduces downtime.
-
-
Large Coverage Capacity
-
Up to 6,000 sq. ft. for concrete curing.
-
Up to 18,000 sq. ft. for ground thawing.
-
Specifications of the Wacker Neuson - E3000 HYD SUR HTR,6KW GEN, LB, EXT SVC - 5100056441
-
Model Number: 5100056441
-
Type: Hydronic surface heater with integrated generator, load bank, and extended service package
-
Generator Output: 6kW
-
Coverage:
-
Concrete curing: up to 6,000 sq. ft.
-
Ground thawing: up to 18,000 sq. ft.
-
-
Hose Capacity: Supports up to 3,000 ft of hose
-
Fuel Type: Diesel
-
Runtime: Extended runtimes with efficient fuel usage
-
Applications: Concrete curing, frost prevention, ground thawing, jobsite heating
Benefits of the Wacker Neuson E3000 HYD SUR HTR
1. Reliable Cold-Weather Performance
Even in subzero temperatures, the E3000 provides steady, even heat that keeps projects moving.
2. Improved Concrete Quality
Maintains curing temperatures to ensure concrete develops full strength without cracks or weaknesses caused by freezing.
3. Extended Service Life
The EXT SVC package increases uptime by reducing maintenance frequency, making it ideal for contractors who run equipment continuously.
4. Safe, Flameless Heating
No open flames, making it safe for enclosed areas and compliance with safety standards.
5. Cost Efficiency
Fuel-efficient design lowers operational costs while reducing downtime.
Applications of the E3000 Hydronic Heater
-
Concrete Curing
-
Maintains optimum curing temperatures in freezing weather.
-
Prevents frost damage and compromised structural integrity.
-
-
Ground Thawing
-
Softens frozen soil for excavation, trenching, and utility installation.
-
Saves time on winter projects.
-
-
Frost Prevention
-
Protects foundations, pipelines, and sensitive areas from frost penetration.
-
-
Jobsite Heating
-
Supplemental heating for workers, equipment, and materials.
-
-
Infrastructure Projects
-
Widely used in bridges, highways, road construction, and large industrial sites.
-
Advantages of Hydronic Heating Over Traditional Heating
Feature | Hydronic Heating (E3000) | Traditional Direct-Fired Heating |
---|---|---|
Heat Distribution | Even and consistent | Uneven with hot spots |
Safety | Flameless, safer on jobsites | Open flames increase fire risks |
Concrete Curing Quality | Prevents cracks and weaknesses | High risk of poor curing |
Efficiency | High fuel efficiency | Lower efficiency, more fuel used |
Coverage | Up to 18,000 sq. ft. | Limited zones only |
This table shows why hydronic heaters like the E3000 HYD SUR HTR are the professional choice for winter construction.
Best Practices for Using the E3000 HYD SUR HTR
-
Plan Hose Layout: Lay hoses evenly to avoid cold spots.
-
Use Proper Glycol Mixture: Prevents internal freezing and system damage.
-
Monitor Fuel and Generator Output: Maintain efficiency with consistent checks.
-
Regular Inspections: Look for hose leaks, wear, or generator irregularities.
-
Train Operators: Proper use ensures maximum efficiency and safety.
Safety Considerations
-
Wear proper PPE when handling hoses and fuel.
-
Keep hoses clear of sharp edges, vehicles, or equipment traffic.
-
Ensure ventilation when used near enclosed spaces.
-
Follow all Wacker Neuson guidelines for generator and load bank usage.
Cost and Investment Value
While the Wacker Neuson - E3000 HYD SUR HTR,6KW GEN, LB, EXT SVC - 5100056441 requires a higher upfront investment, its fuel efficiency, extended service intervals, and ability to prevent costly delays make it a smart purchase. Contractors often recover costs quickly by maintaining project timelines during severe winter months.
Conclusion
The Wacker Neuson - E3000 HYD SUR HTR,6KW GEN, LB, EXT SVC - 5100056441 is one of the most advanced hydronic heating solutions available for professional construction. With its 6kW generator, load bank protection, extended service intervals, and large heating capacity, it keeps projects moving even in extreme cold.
From concrete curing to ground thawing and frost prevention, this heater is a versatile and essential investment for contractors who want to reduce downtime, ensure safety, and maximize productivity year-round.
For demanding winter jobsites, the E3000 is more than just equipment—it’s a solution that guarantees efficiency, safety, and reliability when it matters most.