Adding product to your cart
HI 400HD G Indirect Air Heater
Material number
5000620701
Heavy duty, indirect natural gas/propane heater, 1"x20" supply
5000620701 Categories
Product Detalis
- Produce clean, dry heat without use of an open flame, combustion carbons or water, ideal for a variety of applications
- Units run at 85% efficiency due to 2nd blower for combustion
Diesel model features 2 stage burner with low-fire setting for fuel savings during low heat periods
- Natural gas model features adjustable ball value to switch from natural gas to propane with ease
- 30 hour continuous run time with low-fire setting
- Includes safety locking device to prevent valve movement, 100% stainless steel burner head and gas pipe and large pneumatic tires for portability
- All machines include -40°F cold weather kit
- Optional 20" return air adapter to recirculate warm air and 4" burner supply air duct allows warm air to preheat combustion air
- Includes operator's manual, lift bail and fork pockets
- Trailer sold separately
Technical Specifications:
OPERATING FLUIDS |
Imperial |
Metric |
Fuel Consumption Propane |
3,6 GPH US |
13,8 L/Std |
Fuel Consumption Natural Gas |
44,5 gal/mi |
168,3 l/min |
Fuel specification |
Natural gas |
Natural gas |
GENERATOR |
Imperial |
Metric |
Genset |
no |
no |
SHIPPING AND STORAGE |
Imperial |
Metric |
Width for shipping |
29,1 " |
739 mm |
Length for shipping |
85,8 " |
2.179 mm |
Height for shipping |
49,6 " |
1.260 mm |
ELECTRICAL - OUTPUT DETAILS |
Imperial |
Metric |
Nominal current |
15,00 A |
15,00 A |
Nominal voltage |
120 V |
120 V |
MECHANICAL DETAILS |
Imperial |
Metric |
Operating weight |
3.900,0 lb |
1.769,0 kg |
Duct Length max., 1x20" Supply |
100,1 Foot |
30,50 m |
Duct Length max., 1x20"Return |
298,6 Foot |
91,00 m |
Length |
81,2 " |
2.063 mm |
Duct Length max., 3x12" Supply |
249,3 Foot |
76,00 m |
Lift Bail - quantity |
1 |
1 |
Duct Length max., 2x16" Supply |
60,0 Foot |
18,30 m |
Dry Weight |
2.539,7 lb |
1.152,0 kg |
Height |
48,8 " |
1.240 mm |
Width |
34,0 " |
864 mm |
ENVIRONMENT DATA |
Imperial |
Metric |
Sound level LpA |
74,0 dB(A) |
74,0 dB(A) |
THERMAL - OUTPUT DETAILS |
Imperial |
Metric |
Burner Pressure (Propane) |
1.624 Pa |
1.624 Pa |
Power Output, Blower |
0,75 kW |
0,75 kW |
Static Pressure (Blower) |
125 Pa |
125 Pa |
Heater Net output(Natural Gas) |
95,30 kW |
95,30 kW |
Blower Type |
Axial blower |
Axial blower |
Air flow rate |
3.014,7 cfm |
5.122,5 m3/h |
Heater, Net output (Propane) |
91,70 kW |
91,70 kW |
Burner Pressure (Natural Gas) |
1.594 Pa |
1.594 Pa |
Power Output, Burner Blower |
0,19 W |
0,19 W |
Comes With
Includes operator's manual, lift bail and fork pockets