Adding product to your cart
G150 Generator, Standard T4i
5200023235Categories
Power ,Mobile Generators ,Product Detalis
Digital controller monitors and protects engine
Environmentally friendly features include 115% fluid containment, crankcase oil vapor recovery system, no mess oil
and radiator drain hoses and fast fuel fill system
Brushless alternators with separate excitation and AVR (Automatic Voltage Regulation) for excellent motor starting
Up to 120F (49C) rated power even in hot climates
Easy to use LCD keypad for service diagnostics
Heavy-duty, tandem-axle trailers also available
ELECTRICAL SYSTEM-1
Receptacle Type : NEMA SS2,TL,125/250V,50A
Number of Sockets : 5
ELECTRICAL SYSTEM-2
Receptacle Type : NEMA SS2,TL,125/250V,50A
Number of Sockets : 5
Main Circuit Breaker Rating : 400 A
Available voltages 1~(2) : 120 V
Available voltages 3~(2) : 208 V
ENVIRONMENT DATA-1
Sound level LpA : 70,2 dB(A)
ENVIRONMENT DATA-2
Sound level LpA : 70,2 dB(A)
Engine-1
Cooling : water-cooling
Engine type : Diesel engine
Engine operating mode : four-stroke
Fuel : Diesel EN 590
Cylinder : 4
Cylinder capacity : 4.500 cm3
Tank capacity : 710,00 l
Oil filling max. : 14,50 l
Engine Manufacturer : Cummins
Nominal Engine speed : 1.800 1/min
Effective power : 154,0 KW
Standard (Effective power) : ISO 3046
Exhaust-gas limit : IIIB/Tier IV Final
Starter battery Voltage : 12 V
Battery Cold-start current CCA : 950 A
Engine-2
Engine type : Diesel engine
Engine operating mode : four-stroke
Fuel : Diesel EN 590
Cylinder : 4
Cylinder capacity : 274,6 Inch3
Tank capacity : 187,6 gal US
Oil filling max. : 3,8 gal US
Engine Manufacturer : Cummins
Nominal Engine speed : 1.800 1/min
Effective power : 206,5 hp
Cooling : water-cooling
Standard (Effective power) : ISO 3046
Starter battery Voltage : 12 V
Exhaust-gas limit : IIIB/Tier IV Final
Battery Cold-start current CCA : 950 A
SHIPPING AND STORAGE-1
Shipping weight : 3.225,00 kg
Width for shipping : 1.384 mm
Height for shipping : 2.184 mm
Length for shipping : 3.442 mm
Shipping weight (with Trailer) : 3.729,0 kg
Height shipping (with Trailer) : 2.603 mm
Width shipping (with Trailer) : 2.146 mm
Length shipping (with Trailer) : 5.055 mm
SHIPPING AND STORAGE-2
Shipping weight : 7.109,9 lb
Width for shipping : 54,5 "
Height for shipping : 86,0 "
Length for shipping : 135,5 "
Shipping weight (with Trailer) : 8.221,0 lb
Height shipping (with Trailer) : 102,5 "
Width shipping (with Trailer) : 84,5 "
Length shipping (with Trailer) : 199,0 "
ELECTRICAL - OUTPUT DETAILS-1
Nominal power [P] : 121,00 KW
Nominal power [S] : 163,00 kVA
ELECTRICAL - OUTPUT DETAILS-2
Nominal power [P] : 121,00 KW
Nominal power [S] : 163,00 kVA
MECHANICAL DETAILS-1
Length : 2.794 mm
Width : 1.143 mm
Height : 1.685 mm
Operating weight : 2.902,0 kg
Dry Weight : 2.404,0 kg
Operating Weight (w. Trailer) : 3.524 kg
MECHANICAL DETAILS-2
Length : 110,0 "
Width : 45,0 "
Height : 66,3 "
Operating weight : 6.397,8 lb
Dry Weight : 5.299,9 lb
Operating Weight (w. Trailer) : 7.769,1 lb
OPERATING FLUIDS-1
Tank capacity : 710,00 l
Run Time (Prime Load) : 20,4 hrs
Fuel consumption (Prime load) : 32,0 L/hr
Cooling fluid volume : 43,00 l
Run Time DEF (Prime Load) : 21,4 hrs
Run Time (75 %) : 27,1 hrs
AdBlue / DEF Type : AUS 32
Tank capacity AdBlue/DEF : 33,0 l
Fuel consum. DEF (Prime load) : 1,45 L/hr
Run Time (25 %) : 64,5 hrs
Run Time (50 %) : 38,9 hrs
OPERATING FLUIDS-2
Run Time (75 %) : 27,1 hrs
Tank capacity : 187,6 gal US
Cooling fluid volume : 45,4 qt US
Run Time (Prime Load) : 20,4 hrs
Fuel consumption (Prime load) : 8,5 GPH US
Run Time DEF (Prime Load) : 21,4 hrs
Tank capacity AdBlue/DEF : 69,7 pt US
Run Time (50 %) : 38,9 hrs
AdBlue / DEF Type : AUS 32
Run Time (25 %) : 64,5 hrs
Fuel consum. DEF (Prime load) : 0,4 GPH US
GENERATOR-1
Output frequency : 60 Hz
Output current 1~ : 316,0 A
Phase : 1 ~
Efficiency factor 1~ : 1,00 cos
Voltage 1~ : 120 V
Generator specification : AVR without Brushes
Voltage accuracy : 1,0 %
Regulation [U] - Steady State : 0,2 %
Gen. Rating 1~ (Cont.) [kVA] : 84 kVA
Gen. Rating 3~ (Cont.) [kVA] : 180 kVA
Generator Manufacturer : Mecc Alte
Efficiency factor 3~ : 0,80 cos
Voltage 3~ : 240 V
Output current 3~ : 182,0 A
GENERATOR-2
Output current 1~ 316,0 A
Phase 1 ~
Output frequency 60 Hz
Efficiency factor 1~ 1,00 cos
Generator specification AVR without Brushes
Voltage 1~ 120 V
Voltage accuracy 1,0 %
Gen. Rating 3~ (Cont.) [kVA] 180 kVA
Regulation [U] - Steady State 0,2 %
Gen. Rating 1~ (Cont.) [kVA] 84 kVA
Generator Manufacturer Mecc Alte
Efficiency factor 3~ 0,80 cos
Voltage 3~ 240 V
Output current 3~ 182,0 A
Comes With
Includes operator's manual and parts bookGenerator and trailer sold separately